The application of Oxidation Reduction Potential (ORP) sensor in water and wastewater treatment industries
Subject Areas : Water and wastewater technology
1 - University of Tehran
Keywords: Oxidation Reduction Potential, Cyanide detoxification, hydroxyl radicals, fenton,
Abstract :
The Oxidation Reduction Potential (ORP) is applied for controlling the chemical and biological reactions. It means, by the help of ORP the tendency of reactions for occurring in aqueous solution are measured. The ORP measurement has been used in variety of applications especially, water and wastewater treatment e.g. cyanide detoxification, advanced oxidation processes (production of hydroxyl radicals: fenton), water disinfection and etc. By measuring the ORP during the reaction, the end time of reaction, the required concentration of reactants and optimum conditions be determined. In this study, the use of ORP in most common reactions in water and wastewater industries are investigated.
1- Y. Kim, H. Nam, Y. Park, J. Lee, T. Park, T. Lee., “Fenton Oxidation Process Control Using Oxidation-reduction Potential Measurement for Pigment Wastewater Treatment” Korean J. Chem. Eng., 21(4), 801-805 (2004)
2- R. Yu., C. Lin, H. Chen, W. Cheng, M Kao, “Possible control approaches of the Electro-Fenton process for textile wastewater treatment using on-line monitoring of DO and ORP” Chemical Engineering Journal 218 (2013) 341–349
3- R. Priambodo, Y. Shih, Y. Huang, Y. Huang, “Treatment of real wastewater using semi batch (Photo)-Electro-Fenton method” Sustain. Environ. Res., 21(6), 389-393 (2011)