Design and Analysis of a Novel Robust and Fast Sliding-Mode Control with Multi-Slope Sliding Surface for Single-Phase Three Level NPC Inverters under Different Loads and Reduce the Output THD
Subject Areas : electrical and computer engineeringB. Khajeh-Shalaly 1 , G. Shahgholian 2
1 -
2 - Islamic Azad University, Najafabad Branch
Keywords: Sliding Mode Control (SMC) Total Harmonic Distortion (THD) Pulse Width Modulation (PWM),
Abstract :
In this paper control structure with robust performance in presence of parametric uncertainties of the converter in order to improve pure sinusoidal inverter in whole functional and loading conditions is rendered. The controller guarantees fast and accurate behavior of the converter in order to increase the output voltage quality and reduce output harmonics. This controller by sliding performance and utilizing output voltage and capacitor current used in the control process, not only has exact output voltage tracking from reference but also has ability to reject the periodic disturbances due to loading. Also, it guides error states to zero rapidly and makes transient states of the converter as well as possible at error moments that is the same high spikes and loads in output current. Another characteristic of the proposed controller is, improved stability region under wide ranges of loading in different conditions. Accuracy of proposed controller on a single-phase three level NPC inverter which has high sensitivity in control in order to increase quality, decrease harmonics and THD output has been compared with a single-slope sliding mode controller with the sane loading conditions and reference. The simulations results are obtained by MATLAB.
[1] A. Masaoud, H. W. Ping, S. Mekhilef, A. Taallah, and H. Belkamel, "Design and implementation of a new multilevel DC-link three-phase inverter," J. of Power Electronics, vol. 14, no. 2, pp. 292-301, Mar. 2014.
[2] C. Zhang, J. M. Guerrero, J. C. Vasquez, and E. A. A. Coelho, "Control architecture for parallel-connected inverters in uninterruptible power systems," IEEE Trans. on Power Electronics, vol. 31, no. 7, pp. 5176-5188, Jan. 2016.
[3] H. Deng, R. Oruganti, and D. Srinivasan, "Analysis and design of iterative learning control strategies for UPS inverters," IEEE Trans. on Power Electronics, vol. 54, no. 3, pp. 1739-1751, Jun. 2007.
[4] M. Aamir, K. A. Kalwar, and S. Mekhilef, "Review: uninterruptible power supply (UPS) system," Renewable and Sustainable Energy Reviews, vol. 58, no. 1, pp. 1395-1410, May 2016.
[5] K. R. Sekhar and S. Srinivas, "Discontinuous decoupled PWMs for reduced current ripple in a dual two-level inverter fed open-end winding induction motor drive," IEEE Trans. on Power Electronics, vol. 28, no. 5, pp. 2493-2502, Aug. 2012.
[6] G. Shahgholian and N. Izadpanahi, "Improving the performance of wind turbine equipped with DFIG using STATCOM based on input-output feedback linearization controller," Energy Equipment and Systems, vol. 4, no. 1, pp. 65-79, Jun. 2016.
[7] E. Pouresmaeil, D. Montesinos-Miracle, and O. Gomis-Bellmunt, "Control scheme of three-level NPC inverter for integration of renewable energy resources into AC grid," IEEE Systems J., vol. 6, no. 2, pp. 242-253, May 2012.
[8] G. Shahgholian, J. Faiz, and M. Jabbari, "Voltage control techniques in uninterruptible power supply inverters: a review," International Review of Electrical Engineering, vol. 6, no. 4, pp. 1531-1542, Aug. 2011.
[9] J. S. Lim, C. Park, J. Han, and Y. Lee, "Robust tracking control of a three-phase DC-AC inverter for UPS applications," IEEE Trans. on Industrial Electronics, vol. 61, no. 8, pp. 4242-4251, Aug. 2014.
[10] B. Zhang, D. Wang, K. Zhou, and Y. Wang, "Linear phase lead compensation repetitive control of a CVCF PWM inverter," IEEE Trans. on Industrial Electronics, vol. 55, no. 4, pp. 1595-1602, Apr. 2008.
[11] Y. S. Choi, H. H. Choi, and J. W. Jung, "An adaptive sliding-mode control technique for three-phase UPS system with auto-tuning of switching gain," Electrical Engineering, vol. 96, no. 4, pp. 373-383, Dec. 2014.
[12] G. Shahgholian and Z. Azimi, "Analysis and design of a DSTATCOM based on sliding mode control strategy for improvement of voltage sag in distribution systems," Electronics, vol. 5, no. 3, pp. 1-12, Jul. 2016.
[13] A. Hasanzadeh and H. Mokhtari, "A simplified droop method implementation in parallel UPS inverters with proportional-resonant controller," Iranian J. of Science and Technology, Trans. B, Engineering, vol. 33, no. B2, pp. 163-178, Apr. 2009.
[14] H. Zaman, X. Zheng, S. Khan, H. Ali, and X. Wu, "Hysteresis modulation-based sliding-mode current control of z-source DC-DC converter," in Proc. of the IEEE/IPEMC, vol. 1, pp. 321-324, May 2016.
[15] H. Deng, R. Oruganti, and D. Srinivasan, "Neural controller for UPS inverters based on B-spline network," IEEE Trans. on Industrial Electronics, vol. 55, no. 2, pp. 899-909, Feb. 2008.
[16] P. C. Loh, M. J. Newman, D. N. Zmood, and D. G. Holmes, "A comparative analysis of multi-loop voltage regulation strategies for single and three-phase UPS systems," IEEE Trans. on Power Electronics, vol. 18, no. 5, pp. 1176-1185, Sep. 2003.
[17] J. Faiz, G. Shahgholian, and M. Ehsan, "Stability analysis and simulation of a single-phase voltage source UPS inverter with two-stage cascade output filter," European Trans. on Electrical Power, vol. 18, no. 1, pp. 29-49, Jan. 2008.
[18] N. M. Abdel-Rahim and J. E. Quaicoe, "Analysis and design of a multiple feedback loop control strategy for single-phase voltage-source UPS inverters," IEEE Trans. on Power Electronics, vol. 11, no. 3, pp. 532-541, Jul. 1996.
[19] I. Boiko, L. Fridman, and R. Iriarte, "Analysis of chattering in continuous sliding mode control of a buck converter," in Proc. of the IEE/ACC, vol. 4, pp. 2439-2444, Jun. 2005.
[20] O. Kukrer, H. Komurcugil, and A. Doganalp, "A three-level hysteresis function approach to the sliding-mode control of single-phase UPS inverters," IEEE Trans. on Industrial Electronics, vol. 56, no. 9, pp. 3477-3486, Sep. 2009.