Fuzzy Evaluation of Long-Term Impacts of Electrical Appliances Efficiency Improvement on Load Pattern
Subject Areas : electrical and computer engineeringM. Behrangrad 1 , M. Parsa-Moghaddam 2
1 - Tarbiat Modares University
2 - Tarbiat Modares University
Keywords: Load pattern changestrategic conservationelectrical appliancefuzzy modeling,
Abstract :
Evaluation of long-term home electrical appliance efficiency improvement scenarios on load and energy pattern needs comprehensive and precise modeling taking to account a variety of uncertainties. In the modeling process, all effective parameters should be considered. Estimation is the main source of information in this process which is a long-term large scale impact assessment procedure. Furthermore, the non homogeneous structure of load behavior in response to DSM policies makes the problem more sophisticated. The presented method implies fuzzy numbers to model the main uncertainties of the demand side reactions to the proposed DSM program. Here, the social classes of customers and their behaviors regarding energy utilization as well as time dependency of the problem parameters are taken into account. The paper focuses on the efficiency improvement of the electric appliances in Iran as a long-term DSM program, due to their considerable share in electricity consumption in residential sector. Finally, the numerical results are presented.
[1] B. F. Hobbs, H. B. Rouse, and D. T. Hoog, "Measuring the economic value of demand - side and supply resources in integrated resource planning models," IEEE Trans. on Power System, vol. 8, no. 3, pp. 979-987, Aug. 1993.
[2] H. Davoudpour and M. S. Ahadib, "The potential for greenhouse gases mitigation in household sector of Iran: cases of price reform/efficiency improvement and scenario for 2000 - 2010," Energy Policy, vol. 34, no. 1, pp. 40-49, May 2006.
[3] R. M. Shrestha and C. O. P. Marpaung, "Supply and demand - side effects of power sector planning with demand - side management options and SO2 emission constraints," Energy Policy, vol. 33, no. 6, pp. 815-825, Apr. 2005.
[4] G. Wikler, A. Faruqui, C. W. Gehgs, and K. Seiden, "The potential for energy efficiency in electric end - use technologies," IEEE Trans. on Power Systems, vol. 8, no. 3, pp. 1351-1357, Aug. 1993.
[5] M. Fotuhi-Firuzabad and R. bellinton, "Impact of load management on composite system reliability evaluation short-term operating benefits," IEEE Trans. on Power Systems, vol. 15, no. 2, pp. 858-864, May 2000.
[6] E. Vine, J. Sathaye, and E. Orlando, Guidelines for the Monitoring, Evaluation, Reporting, Verification, and Certification of Energy - Efficiency Projects for Climate Change Mitigation, Ernest Orlando Lawrence Berkeley National Laboratory, 1999.
[7] J. Flory and J. S. Peter, "Evaluating DSM: can an engineer count on it?" IEEE Trans. on Power Systems, vol. 9, no. 4, pp. 1752-1758, Nov. 1994.
[8] م. پارسا مقدم، م. بهرنگ راد و م. اقبال، "طراحي شاخصهاي راهنما براي انتخاب بهينه لوازم برقي خانگي،" چهاردهمين كنفرانس مهندسي برق ايران، بهار 1385.
[9] مجله پيك برق، سال يازدهم، شماره 544، 1385.
[10] م. بهرنگ راد و م. پارسا مقدم، "تدوين شاخصهاي اقتصادي و بهرهوري جهت ارزيابي عملكرد وسايل برقي خانگي با رويكرد مديريت مصرف انرژي الكتريكي و تهيه بانك اطلاعاتي،" گزارش پروژه، مركز مطالعات و برنامهريزي شبكههاي قدرت ايران، دانشگاه تربيت مدرس، 1385.